The integrated exterior wall insulation is extremely diverse in terms of decoration and plasticity, which makes it convenient for construction workers to master the operation requirements and ensure the quality of construction. It is applicable to both reconstruction, new construction and expansion of buildings, civil buildings and industrial buildings, load-bearing exterior walls and non-load-bearing exterior walls. When the building height exceeds 30m, metal layering strips should be added, and a layer of metal mesh should be added to the insulation layer (the position of the metal mesh in the insulation layer: the distance from the base wall should not be less than 30mm, the distance from the insulation layer should not be less than 30mm, and the surface should not be greater than 20mm).
Because it is winter, many integrated exterior wall insulation construction sites will soon stop work. Dealers should make good data plans to prevent excessive surplus. The storage environment of the construction site is very unfavorable for the external insulation data. It is firmly combined with the base wall and the surface anti-cracking mortar to ensure the stability of the exterior wall insulation wall. In addition, the surface layer of the insulation material is protected by polymer anti-cracking mortar, which better blocks the penetration of water and completely overcomes the infiltration of rainwater once the organic material insulation wall is damaged.
Whether there are scratches on the integrated surface of the exterior wall insulation, etc., which affect the appearance and use function. Before installing the fixed-length insulation decorative board, each fixed-length board must be carefully checked for quality problems, and the fixed-length boards with problems must be picked out.
In short, the reason why the integrated exterior wall insulation is used instead of brickwork is mainly determined by the following reasons, which is also the advantage of the insulation board itself. It only needs to use the special adhesive of the insulation board to stick it to the mortar layer on the surface of the waterproof protective layer. The anti-cracking protective layer above the insulation layer only needs 3-20mm, and the thermal resistance of the insulation data is relatively large. Therefore, under the same heat condition, the temperature change rate of the external insulation anti-cracking insulation layer is faster than that of the main body under no insulation conditions, which plays a key role in the anti-cracking function of the external insulation system.